Revision History Version 2.0.0.2

Released on 22nd September 2015.

FIXES:

  • Calculation of the Unplugged End Cap when using CLAYICP1 or CLAYICP2 methods in combination with end bearing smoothing is fixed.
  • Without the fix, the Unplugged End Cap calculation considered both the CLAYICP end bearing and the internal shaft friction leading to largely overestimated unplugged capacity when end bearing smoothing was used.
  • Note CLAYICP without end bearing smoothing was not affected. Plugged capacities calculated with CLAYICP were also not affected.